{0;0} 0. Current document units is in Meters 1. Conversion to Meters will be applied = 1.000 2. Current working directory is set to: c:\ladybug\plik_testowy_inz\OpenStudio 3. Duplicate surface name! Name is changed to: SK_Wall_Dup 4. Duplicate surface name! Name is changed to: SK_Wall_Dup_Dup 5. Duplicate surface name! Name is changed to: SK_Wall_Dup_Dup_Dup 6. Duplicate surface name! Name is changed to: SK_Wall_Dup_Dup_Dup_Dup 7. Duplicate surface name! Name is changed to: SK_Wall_Dup_Dup_Dup_Dup_Dup 8. Duplicate surface name! Name is changed to: SK_Wall_Dup_Dup_Dup_Dup_Dup_Dup 9. Duplicate surface name! Name is changed to: SK_Roof_Dup 10. Duplicate surface name! Name is changed to: SK_Ceiling_Dup 11. Duplicate surface name! Name is changed to: SK_Wall_Dup_Dup_Dup_Dup_Dup_Dup_Dup 12. Duplicate surface name! Name is changed to: SK_Roof_Dup_Dup 13. Duplicate surface name! Name is changed to: SK_Ceiling_Dup_Dup 14. Duplicate surface name! Name is changed to: SK_Wall_Dup_Dup_Dup_Dup_Dup_Dup_Dup_Dup 15. Duplicate surface name! Name is changed to: SK_Wall_Dup_Dup_Dup_Dup_Dup_Dup_Dup_Dup_Dup 16. Duplicate surface name! Name is changed to: KS_wall_Dup 17. Duplicate surface name! Name is changed to: KS_wall_Dup_Dup 18. Duplicate surface name! Name is changed to: KS_wall_Dup_Dup_Dup 19. Duplicate surface name! Name is changed to: KS_wall_Dup_Dup_Dup_Dup 20. Duplicate surface name! Name is changed to: KS01_wall_Dup 21. Duplicate surface name! Name is changed to: KS01_floor_Dup 22. Duplicate surface name! Name is changed to: KS01_wall_Dup_Dup 23. Duplicate surface name! Name is changed to: KS01_floor_Dup_Dup 24. Duplicate surface name! Name is changed to: KS01_wall_Dup_Dup_Dup 25. Duplicate surface name! Name is changed to: KS01_wall_Dup_Dup_Dup_Dup 26. Duplicate surface name! Name is changed to: Hall01_floor_Dup 27. Duplicate surface name! Name is changed to: Hall01_floor_Dup_Dup 28. Duplicate surface name! Name is changed to: Hall01_floor_Dup_Dup_Dup 29. Duplicate surface name! Name is changed to: Hall01_floor_Dup_Dup_Dup_Dup 30. Duplicate surface name! Name is changed to: Hall01_wall9_Dup 31. Duplicate surface name! Name is changed to: Hall_Wall_Dup 32. Duplicate surface name! Name is changed to: Hall_Wall_Dup_Dup 33. Duplicate surface name! Name is changed to: Hall_ceiling_Dup 34. Duplicate surface name! Name is changed to: Hall_Airwall_Dup 35. Duplicate surface name! Name is changed to: Hall_Wall_Dup_Dup_Dup 36. Duplicate surface name! Name is changed to: Hall_Wall_Dup_Dup_Dup_Dup 37. Duplicate surface name! Name is changed to: Hall_ceiling_Dup_Dup 38. Duplicate surface name! Name is changed to: Hall_Wall_Dup_Dup_Dup_Dup_Dup 39. Duplicate surface name! Name is changed to: Hall_Wall_Dup_Dup_Dup_Dup_Dup_Dup 40. Duplicate surface name! Name is changed to: Hall_Wall_Dup_Dup_Dup_Dup_Dup_Dup_Dup 41. One of the surfaces has less than 3 identical coordinates and is removed. 42. Adjacent surface Garderoba_Srf_8 was not found. Boundary for surface Garaz_Srf_7 will be set to adiabatic. 43. Adjacent surface SK_Wall was not found. Boundary for surface WC_Srf_2 will be set to adiabatic. 44. Adjacent surface SK_Wall was not found. Boundary for surface WC_Srf_3 will be set to adiabatic. 45. Adjacent surface SK_Wall was not found. Boundary for surface WC_Srf_4 will be set to adiabatic. 46. Adjacent surface SK_Wall was not found. Boundary for surface Hall_Wall_Dup will be set to adiabatic. 47. Adjacent surface SK_Roof was not found. Boundary for surface Pokoj02_Srf_9 will be set to adiabatic. 48. Adjacent surface SK_Roof was not found. Boundary for surface Pokoj02_Srf_8 will be set to adiabatic. 49. Adjacent surface SK_Wall was not found. Boundary for surface Pokoj01_Srf_5 will be set to adiabatic. 50. Adjacent surface SK_Wall was not found. Boundary for surface Pokoj01_Srf_6 will be set to adiabatic. 51. Model saved to: c:\ladybug\plik_testowy_inz\OpenStudio\plik_testowy_inz.osm 52. OSM > IDF: c:/ladybug/plik_testowy_inz/OpenStudio/plik_testowy_inz/ModelToIdf/in.idf 53. Program Version,EnergyPlus, Version 8.9.0-eba93e8e1b, YMD=2018.09.19 21:14, 54. 55. ************* Beginning Zone Sizing Calculations 56. 57. ** Warning ** ProcessScheduleInput: Schedule:Constant="ALWAYS ON DISCRETE", Blank Schedule Type Limits Name input -- will not be validated. 58. 59. ** Warning ** ProcessScheduleInput: Schedule:Constant="ALWAYS OFF DISCRETE", Blank Schedule Type Limits Name input -- will not be validated. 60. 61. ** Warning ** GetHTSurfaceData: Surfaces with interface to Ground found but no "Ground Temperatures" were input. 62. 63. ** ~~~ ** Found first in surface=GARAZ_SRF_0 64. 65. ** ~~~ ** Defaults, constant throughout the year of (18.0) will be used. 66. 67. ** Warning ** GetVertices: Roof/Ceiling is upside down! Tilt angle=[180.0], should be near 0, Surface="HALL01_ROOF", in Zone="HALL01". 68. 69. ** ~~~ ** Automatic fix is attempted. 70. 71. ** Warning ** GetVertices: Floor is upside down! Tilt angle=[0.0], should be near 180, Surface="SK_GROUND", in Zone="KUCHNIA/SALON". 72. 73. ** ~~~ ** Automatic fix is attempted. 74. 75. ** Warning ** GetVertices: Roof/Ceiling is upside down! Tilt angle=[180.0], should be near 0, Surface="SK_ROOF", in Zone="KUCHNIA/SALON". 76. 77. ** ~~~ ** Automatic fix is attempted. 78. 79. ** Warning ** GetSurfaceData: InterZone Surface Areas do not match as expected and might not satisfy conservation of energy: 80. 81. ** ~~~ ** ...use Output:Diagnostics,DisplayExtraWarnings; to show more details on individual mismatches. 82. 83. ** Warning ** GetSurfaceData: InterZone Surface Azimuths do not match as expected. 84. 85. ** ~~~ ** Azimuth=180.0, Tilt=90.0, in Surface=HALL_AIRWALL, Zone=HALL 86. 87. ** ~~~ ** Azimuth=180.0, Tilt=90.0, in Surface=A1E736C704CD4087A2A3, Zone=KSCHOD 88. 89. ** ~~~ ** ..surface class of first surface=Wall 90. 91. ** ~~~ ** ..surface class of second surface=Wall 92. 93. ** Warning ** GetSurfaceData: InterZone Surface Azimuths do not match as expected. 94. 95. ** ~~~ ** Azimuth=270.0, Tilt=90.0, in Surface=HALL_WALL, Zone=HALL 96. 97. ** ~~~ ** Azimuth=270.0, Tilt=90.0, in Surface=POKOJ01_SRF_9, Zone=POKOJ01 98. 99. ** ~~~ ** ..surface class of first surface=Wall 100. 101. ** ~~~ ** ..surface class of second surface=Wall 102. 103. ** Warning ** GetSurfaceData: InterZone Surface Azimuths do not match as expected. 104. 105. ** ~~~ ** Azimuth=90.0, Tilt=90.0, in Surface=HALL_WALL_DUP_DUP_DUP_DUP_DUP_DUP, Zone=HALL 106. 107. ** ~~~ ** Azimuth=0.0, Tilt=90.0, in Surface=KS_WALL, Zone=KSCHOD 108. 109. ** ~~~ ** ..surface class of first surface=Wall 110. 111. ** ~~~ ** ..surface class of second surface=Wall 112. 113. ** Severe ** For zone: KUCHNIA/SALON it is not possible to calculate the volume from the surrounding surfaces so either provide the volume value or define all the surfaces to fully enclose the zone. 114. 115. ** Warning ** Indicated Zone Volume <= 0.0 for Zone=KUCHNIA/SALON 116. 117. ** ~~~ ** The calculated Zone Volume was=0.00 118. 119. ** ~~~ ** The simulation will continue with the Zone Volume set to 10.0 m3. 120. 121. ** ~~~ ** ...use Output:Diagnostics,DisplayExtraWarnings; to show more details on individual zones. 122. 123. ** Warning ** CalculateZoneVolume: 5 zones are not fully enclosed. For more details use: Output:Diagnostics,DisplayExtrawarnings; 124. 125. ** Warning ** DetermineShadowingCombinations: There are 8 surfaces which are receiving surfaces and are non-convex. 126. 127. ** ~~~ ** ...Shadowing values may be inaccurate. Check .shd report file for more surface shading details 128. 129. ** ~~~ ** ...Add Output:Diagnostics,DisplayExtraWarnings; to see individual warnings for each surface. 130. 131. ** Severe ** DetermineShadowingCombinations: There are 3 surfaces which are casting surfaces and are non-convex. 132. 133. ** ~~~ ** ...Shadowing values may be inaccurate. Check .shd report file for more surface shading details 134. 135. ** ~~~ ** ...Add Output:Diagnostics,DisplayExtraWarnings; to see individual severes for each surface. 136. 137. ** Warning ** ManageSizing: For a plant sizing run, there must be at least 1 Sizing:Plant object input. SimulationControl Plant Sizing option ignored. 138. 139. ************* Testing Individual Branch Integrity 140. 141. ************* All Branches passed integrity testing 142. 143. ************* Testing Individual Supply Air Path Integrity 144. 145. ************* All Supply Air Paths passed integrity testing 146. 147. ************* Testing Individual Return Air Path Integrity 148. 149. ************* All Return Air Paths passed integrity testing 150. 151. ************* No node connection errors were found. 152. 153. ************* Beginning Simulation 154. 155. ** Warning ** The resource referenced by LifeCycleCost:UsePriceEscalation= "U.S. AVG COMMERCIAL-ELECTRICITY" has no energy cost. 156. 157. ** ~~~ ** ... It is likely that the wrong resource is used. The resource should match the meter used in Utility:Tariff. 158. 159. ** Warning ** The resource referenced by LifeCycleCost:UsePriceEscalation= "U.S. AVG COMMERCIAL-DISTILLATE OIL" has no energy cost. 160. 161. ** ~~~ ** ... It is likely that the wrong resource is used. The resource should match the meter used in Utility:Tariff. 162. 163. ** Warning ** The resource referenced by LifeCycleCost:UsePriceEscalation= "U.S. AVG COMMERCIAL-RESIDUAL OIL" has no energy cost. 164. 165. ** ~~~ ** ... It is likely that the wrong resource is used. The resource should match the meter used in Utility:Tariff. 166. 167. ** Warning ** The resource referenced by LifeCycleCost:UsePriceEscalation= "U.S. AVG COMMERCIAL-NATURAL GAS" has no energy cost. 168. 169. ** ~~~ ** ... It is likely that the wrong resource is used. The resource should match the meter used in Utility:Tariff. 170. 171. ** Warning ** The resource referenced by LifeCycleCost:UsePriceEscalation= "U.S. AVG COMMERCIAL-COAL" has no energy cost. 172. 173. ** ~~~ ** ... It is likely that the wrong resource is used. The resource should match the meter used in Utility:Tariff. 174. 175. ************* Simulation Error Summary ************* 176. 177. ** Warning ** The following Report Variables were requested but not generated -- check.rdd file 178. 179. ** ~~~ ** Either the IDF did not contain these elements, the variable name is misspelled, 180. 181. ** ~~~ ** or the requested variable is an advanced output which requires Output : Diagnostics, DisplayAdvancedReportVariables; 182. 183. ************* Key=*, VarName=FAN ELECTRIC ENERGY, Frequency=Hourly 184. 185. ************* Key=*, VarName=ZONE VENTILATION FAN ELECTRIC ENERGY, Frequency=Hourly 186. 187. ************* Key=*, VarName=PUMP ELECTRIC ENERGY, Frequency=Hourly 188. 189. ************* Key=*, VarName=ZONE VRF AIR TERMINAL COOLING ELECTRIC ENERGY, Frequency=Hourly 190. 191. ************* Key=*, VarName=ZONE VRF AIR TERMINAL HEATING ELECTRIC ENERGY, Frequency=Hourly 192. 193. ************* Key=*, VarName=VRF HEAT PUMP COOLING ELECTRIC ENERGY, Frequency=Hourly 194. 195. ************* Key=*, VarName=VRF HEAT PUMP HEATING ELECTRIC ENERGY, Frequency=Hourly 196. 197. ************* Key=*, VarName=COOLING COIL ELECTRIC ENERGY, Frequency=Hourly 198. 199. ************* Key=*, VarName=CHILLER ELECTRIC ENERGY, Frequency=Hourly 200. 201. ************* Key=*, VarName=BOILER GAS ENERGY, Frequency=Hourly 202. 203. ************* Key=*, VarName=HEATING COIL TOTAL HEATING ENERGY, Frequency=Hourly 204. 205. ************* Key=*, VarName=HEATING COIL GAS ENERGY, Frequency=Hourly 206. 207. ************* Key=*, VarName=HEATING COIL ELECTRIC ENERGY, Frequency=Hourly 208. 209. ************* Key=*, VarName=HUMIDIFIER ELECTRIC ENERGY, Frequency=Hourly 210. 211. ************* There are 3 unused schedules in input. 212. 213. ************* There are 3 unused week schedules in input. 214. 215. ************* There are 3 unused day schedules in input. 216. 217. ************* Use Output:Diagnostics,DisplayUnusedSchedules; to see them. 218. 219. ************* 220. 221. ************* ===== Final Error Summary ===== 222. 223. ************* The following error categories occurred. Consider correcting or noting. 224. 225. ************* InterZone Surface Areas -- mismatch 226. 227. ************* ..Area mismatch errors happen when the interzone surface in zone A is 228. 229. ************* ..not the same size as it's companion in zone B. 230. 231. ************* InterZone Surface Azimuths -- mismatch 232. 233. ************* ..The azimuths (outward facing angle) of two interzone surfaces should not be the same. 234. 235. ************* ..Normally, the absolute difference between the two azimuths will be 180 degrees. 236. 237. ************* ..You can turn on the report: Output:Surfaces:List,Details; to inspect your surfaces. 238. 239. ************* 240. 241. ************* EnergyPlus Warmup Error Summary. During Warmup: 0 Warning; 0 Severe Errors. 242. 243. ************* EnergyPlus Sizing Error Summary. During Sizing: 13 Warning; 1 Severe Errors. 244. 245. ************* EnergyPlus Completed Successfully-- 27 Warning; 4 Severe Errors; Elapsed Time=00hr 00min 29.55sec 246.