{0;0;0} 0. Current document units is in Meters 1. Conversion to Meters will be applied = 1.000 2. Current working directory is set to: c:\ladybug\unnamed\OpenStudio 3. Duplicate surface name! Name is changed to: wall3_Dup 4. Currently OpenStudio component des not support .csv file as a schedule. The schedule: C:\LADYBUG\EPCSVSCHEDULES\SCHMORBLINDSSCHEDULE.CSV will be written into IDF after it is translated from an OSM. 5. Currently OpenStudio component des not support .csv file as a schedule. The schedule: C:\LADYBUG\EPCSVSCHEDULES\SCHMORBLINDSSCHEDULE.CSV will be written into IDF after it is translated from an OSM. 6. Currently OpenStudio component des not support .csv file as a schedule. The schedule: C:\LADYBUG\EPCSVSCHEDULES\SCHMORBLINDSSCHEDULE.CSV will be written into IDF after it is translated from an OSM. 7. Currently OpenStudio component des not support .csv file as a schedule. The schedule: C:\LADYBUG\EPCSVSCHEDULES\SCHMORBLINDSSCHEDULE.CSV will be written into IDF after it is translated from an OSM. 8. too many values to unpack 9. Model saved to: c:\ladybug\unnamed\OpenStudio\unnamed.osm 10. OSM > IDF: c:/ladybug/unnamed/OpenStudio/unnamed/ModelToIdf/in.idf 11. Program Version,EnergyPlus, Version 9.2.0-921312fa1d, YMD=2020.04.14 10:28, 12. 13. ************* Beginning Zone Sizing Calculations 14. 15. ** Warning ** ProcessScheduleInput: Schedule:Constant="ALWAYS OFF DISCRETE", Blank Schedule Type Limits Name input -- will not be validated. 16. 17. ** Warning ** GetHTSurfaceData: Surfaces with interface to Ground found but no "Ground Temperatures" were input. 18. 19. ** ~~~ ** Found first in surface=FLOOR4 20. 21. ** ~~~ ** Defaults, constant throughout the year of (18.0) will be used. 22. 23. ** Warning ** WindowShadingControl="SHADING CONTROL 1", The first SetPoint is zero. 24. 25. ** ~~~ ** ..You may have forgotten to specify that setpoint. 26. 27. ** Warning ** WindowShadingControl="SHADING CONTROL 2", The first SetPoint is zero. 28. 29. ** ~~~ ** ..You may have forgotten to specify that setpoint. 30. 31. ** Warning ** WindowShadingControl="SHADING CONTROL 3", The first SetPoint is zero. 32. 33. ** ~~~ ** ..You may have forgotten to specify that setpoint. 34. 35. ** Warning ** WindowShadingControl="SHADING CONTROL 4", The first SetPoint is zero. 36. 37. ** ~~~ ** ..You may have forgotten to specify that setpoint. 38. 39. ************* Note that the following warning(s) may/will occur if you have not enclosed your zone completely. 40. 41. ** Warning ** Entered Zone Volumes differ from calculated zone volume(s). 42. 43. ** ~~~ ** ...use Output:Diagnostics,DisplayExtraWarnings; to show more details on individual zones. 44. 45. ** Warning ** CheckUsedConstructions: There are 2 nominally unused constructions in input. 46. 47. ** ~~~ ** For explicit details on each unused construction, use Output:Diagnostics,DisplayExtraWarnings; 48. 49. ** Warning ** AssociateWindowShadingControlWithDaylighting: Daylighting object name used in WindowShadingControl not found. 50. 51. ** ~~~ ** ..The WindowShadingControl object="SHADING CONTROL 1" and referenes an object named: "" 52. 53. ** Warning ** AssociateWindowShadingControlWithDaylighting: Daylighting object name used in WindowShadingControl not found. 54. 55. ** ~~~ ** ..The WindowShadingControl object="SHADING CONTROL 2" and referenes an object named: "" 56. 57. ** Warning ** AssociateWindowShadingControlWithDaylighting: Daylighting object name used in WindowShadingControl not found. 58. 59. ** ~~~ ** ..The WindowShadingControl object="SHADING CONTROL 3" and referenes an object named: "" 60. 61. ** Warning ** AssociateWindowShadingControlWithDaylighting: Daylighting object name used in WindowShadingControl not found. 62. 63. ** ~~~ ** ..The WindowShadingControl object="SHADING CONTROL 4" and referenes an object named: "" 64. 65. ** Warning ** UpdateZoneSizing: Cooling supply air temperature (calculated) within 5C of zone temperature 66. 67. ** ~~~ ** ...check zone thermostat set point and design supply air temperatures 68. 69. ** ~~~ ** ...zone name = BEDROOM1 70. 71. ** ~~~ ** ...design sensible cooling load = 1295.14 W 72. 73. ** ~~~ ** ...thermostat set point temp = 0.000 C 74. 75. ** ~~~ ** ...zone temperature = 21.500 C 76. 77. ** ~~~ ** ...supply air temperature = 18.000 C 78. 79. ** ~~~ ** ...temperature difference = -3.49983 C 80. 81. ** ~~~ ** ...calculated volume flow rate = 0.30099 m3/s 82. 83. ** ~~~ ** ...calculated mass flow rate = 0.36258 kg/s 84. 85. ** Warning ** UpdateZoneSizing: Cooling supply air temperature (calculated) within 5C of zone temperature 86. 87. ** ~~~ ** ...check zone thermostat set point and design supply air temperatures 88. 89. ** ~~~ ** ...zone name = BEDROOM2 90. 91. ** ~~~ ** ...design sensible cooling load = 1752.47 W 92. 93. ** ~~~ ** ...thermostat set point temp = 0.000 C 94. 95. ** ~~~ ** ...zone temperature = 21.500 C 96. 97. ** ~~~ ** ...supply air temperature = 18.000 C 98. 99. ** ~~~ ** ...temperature difference = -3.49976 C 100. 101. ** ~~~ ** ...calculated volume flow rate = 0.40729 m3/s 102. 103. ** ~~~ ** ...calculated mass flow rate = 0.49061 kg/s 104. 105. ** Warning ** UpdateZoneSizing: Cooling supply air temperature (calculated) within 5C of zone temperature 106. 107. ** ~~~ ** ...check zone thermostat set point and design supply air temperatures 108. 109. ** ~~~ ** ...zone name = LIVINGROOM 110. 111. ** ~~~ ** ...design sensible cooling load = 1236.66 W 112. 113. ** ~~~ ** ...thermostat set point temp = 0.000 C 114. 115. ** ~~~ ** ...zone temperature = 21.499 C 116. 117. ** ~~~ ** ...supply air temperature = 18.000 C 118. 119. ** ~~~ ** ...temperature difference = -3.49934 C 120. 121. ** ~~~ ** ...calculated volume flow rate = 0.28744 m3/s 122. 123. ** ~~~ ** ...calculated mass flow rate = 0.34625 kg/s 124. 125. ************* Beginning System Sizing Calculations 126. 127. ** Warning ** GetAirPathData: AirLoopHVAC="AIR LOOP HVAC 1" has no Controllers. 128. 129. ************* Beginning Plant Sizing Calculations 130. 131. ** Warning ** Capacity ratio as a function of temperature curve output is not equal to 1.0 132. 133. ** ~~~ ** (+ or - 10%) at reference conditions for ChillerHeaterPerformance:Electric:EIR= CHILLER HEATER PERFORMANCE ELECTRIC EIR 1 134. 135. ** ~~~ ** Curve output at reference conditions = 1.202 136. 137. ** Warning ** Energy input ratio as a function of temperature curve output is not equal to 1.0 138. 139. ** ~~~ ** (+ or - 10%) at reference conditions for ChillerHeaterPerformance:Electric:EIR= CHILLER HEATER PERFORMANCE ELECTRIC EIR 1 140. 141. ** ~~~ ** Curve output at reference conditions = 0.656 142. 143. ** Warning ** Missing temperature setpoint on cooling side for CentralHeatPumpSystem named CENTRAL HEAT PUMP SYSTEM 1 144. 145. ** ~~~ ** A temperature setpoint is needed at the outlet node of a CentralHeatPumpSystem, use a SetpointManager 146. 147. ** ~~~ ** The overall loop setpoint will be assumed for CentralHeatPumpSystem. The simulation continues ... 148. 149. ** Warning ** Missing temperature setpoint on heating side for CentralHeatPumpSystem named CENTRAL HEAT PUMP SYSTEM 1 150. 151. ** ~~~ ** A temperature setpoint is needed at the outlet node of a CentralHeatPumpSystem, use a SetpointManager 152. 153. ** ~~~ ** The overall loop setpoint will be assumed for CentralHeatPumpSystem. The simulation continues ... 154. 155. ************* Testing Individual Branch Integrity 156. 157. ************* All Branches passed integrity testing 158. 159. ************* Testing Individual Supply Air Path Integrity 160. 161. ************* All Supply Air Paths passed integrity testing 162. 163. ************* Testing Individual Return Air Path Integrity 164. 165. ************* All Return Air Paths passed integrity testing 166. 167. ************* No node connection errors were found. 168. 169. ************* Beginning Simulation 170. 171. ** Severe ** CalcHeatBalanceInsideSurf: The temperature of 3809161.94 C for zone="BEDROOM1", for surface="FLOOR1" 172. 173. ** ~~~ ** ..is very far out of bounds during warmup. This may be an indication of a malformed zone. 174. 175. ** ~~~ ** During Warmup, Environment=RUN PERIOD 1, at Simulation time=01/01 14:30 - 14:31 176. 177. ** Fatal ** Program terminates due to preceding condition. 178. 179. ...Summary of Errors that led to program termination: 180. 181. ..... Reference severe error count=1 182. 183. ..... Last severe error=CalcHeatBalanceInsideSurf: The temperature of 3809161.94 C for zone="BEDROOM1", for surface="FLOOR1" 184. 185. ** Warning ** Check control types on branches between splitter and mixer in PlantLoop=CONDENSER WATER LOOP 186. 187. ** ~~~ ** Found a BYPASS branch with no ACTIVE branch in parallel with it 188. 189. ** ~~~ ** In certain (but not all) situations, this can cause problems; please verify your inputs 190. 191. ** ~~~ ** Bypass branch named: CONDENSER WATER LOOP DEMAND BRANCH 1 192. 193. ** Warning ** Check control types on branches between splitter and mixer in PlantLoop=CONDENSER WATER LOOP 194. 195. ** ~~~ ** Found a BYPASS branch with no ACTIVE branch in parallel with it 196. 197. ** ~~~ ** In certain (but not all) situations, this can cause problems; please verify your inputs 198. 199. ** ~~~ ** Bypass branch named: CONDENSER WATER LOOP DEMAND BYPASS BRANCH 200. 201. ************* 202. 203. ************* ===== Recurring Error Summary ===== 204. 205. ************* The following recurring error messages occurred. 206. 207. ************* 208. 209. ************* ** Warning ** Plant loop exceeding upper temperature limit, PlantLoop="CHILLED WATER LOOP" 210. 211. ************* ** ~~~ ** This error occurred 78 total times; 212. 213. ************* ** ~~~ ** during Warmup 78 times; 214. 215. ************* ** ~~~ ** during Sizing 0 times. 216. 217. ************* ** ~~~ ** Max=60. 218. 219. ************* 220. 221. ************* 222. 223. ************* ===== Final Error Summary ===== 224. 225. ************* The following error categories occurred. Consider correcting or noting. 226. 227. ************* Nominally Unused Constructions 228. 229. ************* ..The nominally unused constructions warning is provided to alert you to potential conditions that can cause 230. 231. ************* ..extra time during simulation. Each construction is calculated by the algorithm indicated in the HeatBalanceAlgorithm 232. 233. ************* ..object. You may remove the constructions indicated (when you use the DisplayExtraWarnings option). 234. 235. ************* 236. 237. ************* EnergyPlus Warmup Error Summary. During Warmup: 0 Warning; 1 Severe Errors. 238. 239. ************* EnergyPlus Sizing Error Summary. During Sizing: 16 Warning; 0 Severe Errors. 240. 241. ************* EnergyPlus Terminated--Fatal Error Detected. 100 Warning; 1 Severe Errors; Elapsed Time=00hr 00min 6.76sec 242.