{0;0;0} 0. Current document units is in Meters 1. Conversion to Meters will be applied = 1.000 2. Current working directory is set to: c:\ladybug\unnamed\OpenStudio 3. Duplicate surface name! Name is changed to: roof3_Dup 4. Duplicate surface name! Name is changed to: wall3_Dup 5. Currently OpenStudio component des not support .csv file as a schedule. The schedule: C:\LADYBUG\EPCSVSCHEDULES\SCHMORBLINDSSCHEDULE.CSV will be written into IDF after it is translated from an OSM. 6. Model saved to: c:\ladybug\unnamed\OpenStudio\unnamed.osm 7. OSM > IDF: c:/ladybug/unnamed/OpenStudio/unnamed/ModelToIdf/in.idf 8. Program Version,EnergyPlus, Version 9.2.0-921312fa1d, YMD=2020.04.15 11:19, 9. 10. ************* Beginning Zone Sizing Calculations 11. 12. ** Warning ** ProcessScheduleInput: Schedule:Constant="ALWAYS OFF DISCRETE", Blank Schedule Type Limits Name input -- will not be validated. 13. 14. ** Warning ** ProcessScheduleInput: Schedule:Constant="ALWAYS ON CONTINUOUS", Blank Schedule Type Limits Name input -- will not be validated. 15. 16. ** Warning ** WindowShadingControl="SHADING CONTROL 1", The first SetPoint is zero. 17. 18. ** ~~~ ** ..You may have forgotten to specify that setpoint. 19. 20. ************* Note that the following warning(s) may/will occur if you have not enclosed your zone completely. 21. 22. ** Warning ** Entered Zone Volumes differ from calculated zone volume(s). 23. 24. ** ~~~ ** ...use Output:Diagnostics,DisplayExtraWarnings; to show more details on individual zones. 25. 26. ** Warning ** CheckUsedConstructions: There are 2 nominally unused constructions in input. 27. 28. ** ~~~ ** For explicit details on each unused construction, use Output:Diagnostics,DisplayExtraWarnings; 29. 30. ** Warning ** UpdateZoneSizing: Cooling supply air temperature (calculated) within 5C of zone temperature 31. 32. ** ~~~ ** ...check zone thermostat set point and design supply air temperatures 33. 34. ** ~~~ ** ...zone name = LIVINGROOM 35. 36. ** ~~~ ** ...design sensible cooling load = 1871.34 W 37. 38. ** ~~~ ** ...thermostat set point temp = 0.000 C 39. 40. ** ~~~ ** ...zone temperature = 21.499 C 41. 42. ** ~~~ ** ...supply air temperature = 18.000 C 43. 44. ** ~~~ ** ...temperature difference = -3.49882 C 45. 46. ** ~~~ ** ...calculated volume flow rate = 0.43503 m3/s 47. 48. ** ~~~ ** ...calculated mass flow rate = 0.52404 kg/s 49. 50. ************* Beginning System Sizing Calculations 51. 52. ** Warning ** GetAirPathData: AirLoopHVAC="AIR LOOP HVAC 1" has no Controllers. 53. 54. ************* Beginning Plant Sizing Calculations 55. 56. ** Warning ** Capacity ratio as a function of temperature curve output is not equal to 1.0 57. 58. ** ~~~ ** (+ or - 10%) at reference conditions for ChillerHeaterPerformance:Electric:EIR= CHILLER HEATER PERFORMANCE ELECTRIC EIR 1 59. 60. ** ~~~ ** Curve output at reference conditions = 1.202 61. 62. ** Warning ** Energy input ratio as a function of temperature curve output is not equal to 1.0 63. 64. ** ~~~ ** (+ or - 10%) at reference conditions for ChillerHeaterPerformance:Electric:EIR= CHILLER HEATER PERFORMANCE ELECTRIC EIR 1 65. 66. ** ~~~ ** Curve output at reference conditions = 0.656 67. 68. ** Warning ** Missing temperature setpoint on cooling side for CentralHeatPumpSystem named CENTRAL HEAT PUMP SYSTEM 1 69. 70. ** ~~~ ** A temperature setpoint is needed at the outlet node of a CentralHeatPumpSystem, use a SetpointManager 71. 72. ** ~~~ ** The overall loop setpoint will be assumed for CentralHeatPumpSystem. The simulation continues ... 73. 74. ** Warning ** Missing temperature setpoint on heating side for CentralHeatPumpSystem named CENTRAL HEAT PUMP SYSTEM 1 75. 76. ** ~~~ ** A temperature setpoint is needed at the outlet node of a CentralHeatPumpSystem, use a SetpointManager 77. 78. ** ~~~ ** The overall loop setpoint will be assumed for CentralHeatPumpSystem. The simulation continues ... 79. 80. ************* Testing Individual Branch Integrity 81. 82. ************* All Branches passed integrity testing 83. 84. ************* Testing Individual Supply Air Path Integrity 85. 86. ************* All Supply Air Paths passed integrity testing 87. 88. ************* Testing Individual Return Air Path Integrity 89. 90. ************* All Return Air Paths passed integrity testing 91. 92. ************* No node connection errors were found. 93. 94. ************* Beginning Simulation 95. 96. ** Severe ** CalcHeatBalanceInsideSurf: The temperature of 1588779.89 C for zone="LIVINGROOM", for surface="FACADE4" 97. 98. ** ~~~ ** ..is very far out of bounds during warmup. This may be an indication of a malformed zone. 99. 100. ** ~~~ ** During Warmup, Environment=RUN PERIOD 1, at Simulation time=01/01 03:21 - 03:23 101. 102. ** Fatal ** Program terminates due to preceding condition. 103. 104. ...Summary of Errors that led to program termination: 105. 106. ..... Reference severe error count=1 107. 108. ..... Last severe error=CalcHeatBalanceInsideSurf: The temperature of 1588779.89 C for zone="LIVINGROOM", for surface="FACADE4" 109. 110. ** Warning ** Check control types on branches between splitter and mixer in PlantLoop=CONDENSER WATER LOOP 111. 112. ** ~~~ ** Found a BYPASS branch with no ACTIVE branch in parallel with it 113. 114. ** ~~~ ** In certain (but not all) situations, this can cause problems; please verify your inputs 115. 116. ** ~~~ ** Bypass branch named: CONDENSER WATER LOOP DEMAND BRANCH 1 117. 118. ** Warning ** Check control types on branches between splitter and mixer in PlantLoop=CONDENSER WATER LOOP 119. 120. ** ~~~ ** Found a BYPASS branch with no ACTIVE branch in parallel with it 121. 122. ** ~~~ ** In certain (but not all) situations, this can cause problems; please verify your inputs 123. 124. ** ~~~ ** Bypass branch named: CONDENSER WATER LOOP DEMAND BYPASS BRANCH 125. 126. ************* 127. 128. ************* ===== Final Error Summary ===== 129. 130. ************* The following error categories occurred. Consider correcting or noting. 131. 132. ************* Nominally Unused Constructions 133. 134. ************* ..The nominally unused constructions warning is provided to alert you to potential conditions that can cause 135. 136. ************* ..extra time during simulation. Each construction is calculated by the algorithm indicated in the HeatBalanceAlgorithm 137. 138. ************* ..object. You may remove the constructions indicated (when you use the DisplayExtraWarnings option). 139. 140. ************* 141. 142. ************* EnergyPlus Warmup Error Summary. During Warmup: 0 Warning; 1 Severe Errors. 143. 144. ************* EnergyPlus Sizing Error Summary. During Sizing: 7 Warning; 0 Severe Errors. 145. 146. ************* EnergyPlus Terminated--Fatal Error Detected. 13 Warning; 1 Severe Errors; Elapsed Time=00hr 00min 0.96sec 147.